Cooling, water and site utilities
The catalogue distinguishes air-cooled values with an “F” suffix and orange data in the standard-pressure tables, while models without “F” are described as water-cooled. This distinction changes package dimensions and weight, and it changes the buyer's utility checklist. For air cooling, confirm maximum ambient temperature, altitude, ventilation path, recirculation risk, inlet cleanliness and the heat rejected to the compressor room. For water cooling, specify inlet temperature, allowable temperature rise, water quality, pressure, flow, fouling allowance, corrosion control and whether the circuit is once-through, tower water or closed loop.
Water-lubricated compression also requires attention to water quality and separator performance. The supplied catalogue illustrates a lubricating-water filtration system, water cooler and water/air separation barrel. The order specification should identify consumables, drainage, water make-up, winterization and the consequences of a utility-water interruption. These details are not fully defined in the catalogue and remain engineering-review items.
Electrical data must include site voltage, phase, frequency, permitted voltage variation, earthing, short-circuit level, motor starting constraints, VFD harmonic requirements where relevant, and the control interface. Catalogue kW and HP values are model-table fields, not a complete electrical schedule.