Product Description
Electric Engine Portable Rotary Screw Air Compressor
Product Parameters
Product Description
Hot Sale Products
2~10bar Oil-injected 7~16bar All-in-1 Small Single-phase
Screw Air Compressor Screw Air Compressor Screw Air Compressor
2~40bar 100% Oil-free 8~12bar 100% Oil-free Diesel Engine Portable
Screw Air Compressor Scroll Air Compressor Screw Air Compressor
Main Product
What we can supply:
* Oil-injected Screw Air Compressor (2~16 bar)
* All-in-1 Screw Air Compressor with Tank, Dryer, and Filters (7~16 bar)
* Single-phase Small Screw Air Compressor for Home use (8~10 bar)
* Water-injected Oil-free Screw Air Compressor (2~40 bar)
* Oil-free Scroll Air Compressor (8~12 bar)
* Diesel&Electric Engine Portable Screw Air Compressor (8~30 bar)
* Air Dryer, Air tank, Filters, and other Spare parts
| After-sales Service: | 24*7 Online Services and Video Guide |
|---|---|
| Warranty: | 1 Year for The Whole Machine & 2 Years for Airend |
| Lubrication Style: | Lubricated |
| Cooling System: | Air Cooling |
| Power Source: | AC Power |
| Installation Type: | Movable Type |
| Customization: |
Available
|
|
|---|

How to Repair and Maintain an Air Compressor
A compressor is a device used to move air from one place to another. Air enters the air compressor through the intake valve. Inside the compressor, the vanes on the inner rotor rotate within an eccentric cavity. The self-adjusting length arm divides the space into multiple cavities of different sizes. As the rotor rotates, air fills the cavity. As air flows around the cavity, it builds pressure and is squeezed out of the compressor output.
Positive displacement
Positive displacement air compressors use reciprocating pistons to compress air. Gas is drawn in during the suction stroke and compressed by moving the piston in the opposite direction. It then discharges the compressed air by moving it in the opposite direction. This type of air compressor is most commonly found in automobiles, refrigerators, and other applications that require high pressure. However, it is not as efficient as a centrifugal compressor.
Most modern air compressors use positive displacement. Positive displacement models capture a volume of air in the compression chamber and distribute it when the pump is operating at maximum capacity. They are more economical than their negative displacement counterparts. Reciprocating screw air compressors are the most common positive displacement compressors. The reciprocating screw air compressor adopts a water jacket around the cylinder and is often used in processes such as oil drilling.
A bicycle pump is an example of positive displacement compression. Air is drawn into the cylinder and compressed by the moving piston. A piston compressor works on the same principle, but it uses a rotating crankshaft or connecting rod to complete the movement of the pistons. There are two types of positive displacement compressors: single-acting and double-acting. Both types work on the same principle, both are positive displacement compressors. The difference between the two types is the pressure ratio.
In air compression, positive displacement compression reduces the volume of the fluid and reduces its viscosity. This results in higher pressure ratios and is used in centrifugal, axial, and scroll compressors. Positive displacement is a common feature of most air compressors. Positive displacement compressors offer the same benefits and are more energy-efficient when applied to oil-free and gas applications. This type of compression is usually the best choice for low-pressure applications.
oil free
If you’re looking for an air compressor for your business, consider an oil-free air compressor. These models offer cleaner, quieter operation than traditional air compressors and require less maintenance. They also meet ISO Class 0 or Class 1 air purity requirements. Oil-free air compressors are also quieter, with fewer moving parts and less noise. These advantages make oil-free air compressors an ideal solution for many commercial applications.
Air purity is critical in many industries. Even the tiniest drop of oil can damage production equipment or damage products. The best way to find an oil-free air compressor for your business is to consider the process and end product. As air quality improves, more and more businesses are turning to oil-free compressors. Some of the advantages and disadvantages of these air compressors are:
When choosing an oil-free air compressor, it is important to understand the terminology used in the industry. Knowing these terms will make it easier for you to choose the right compressor for your needs. ACTFM, or actual cubic feet per minute, is an industry term for measuring the amount of air pumped in one minute under rated conditions. Although a simple number, it can be very useful in determining which type of air compressor is best for your application.
The ISO 8573-1 international standard defines air quality and provides air purity classifications. The strictest classification is air purity class 0. Many manufacturers claim that oil-free air compressors meet this standard. However, a class 0 oil-free air compressor does not necessarily mean that the air is free of contaminants. In fact, Class 0 is the benchmark for air purity. While zero air quality is the highest level, that doesn’t mean it’s completely oil-free.
double acting
A double-acting air compressor is a device that uses compressed air to generate electricity. Its working principle is based on piston and connecting rod. The connecting rod connects the crankshaft to the piston through pins and caps. The piston moves as the piston moves. Rods are usually made of forged carbon steel. In terms of service and maintenance, double-acting compressors require regular vise maintenance and proper cleaning.
The displacement of the compressor is a measure of the displacement that the piston can produce in a certain period of time. Displacement is usually expressed in actual cubic feet per minute. The exact calculation depends on the type of cylinder and the configuration of the compressor. Single-acting cylinders can have head-end or crank-end displacement, both of which can be measured using the displacement equation. A double-acting air compressor will use this equation. 4 and 6 calculate the displacement.
Double-acting air compressors have multiple cylinders and are made of cast iron. They are water-cooled and have a mechanical connection between the piston and connecting rod. A double-acting compressor compresses air twice per revolution of the motor. One cylinder moves up, while the other cylinder moves down. The piston moves down, allowing air to enter through valve #1. During the operation of the compressor, the temperature of the air and gas increases.
Double-acting air compressors typically have high pressure and are considered workhorses. Double-acting compressors also feature intercooling and double compression. As a result, these machines tend to last longer than single-acting compressors. Its low speed and dual compression make it a workhorse in the compressor industry. Double-acting air compressors are workhorses and versatile devices.
fuel tank pressure switch
You can adjust the pressure in the air compressor tank by adjusting the differential pressure. You can turn the mainspring clockwise or counterclockwise to increase or decrease the pressure. This valve will open when the pressure is low enough to start the compressor. If the pressure is too low, the valve should be closed. The cut-in and cut-out pressures should be set to appropriate values. After adjusting the tank pressure, check the hysteresis of the tank pressure switch and set the desired shutoff pressure.
If the pressure in the tank falls below the cut-in level, the tank pressure switch must be replaced. You can test the switch with a multimeter. Make sure the switch is not damaged. If you can’t find the switch, you can look at the other sections. If you find any damaged or missing parts, you should replace them. Otherwise, it may be time to check the tank pressure switch. You may need to disassemble the compressor and remove the switch.
The fuel tank pressure switch is an important part of the air compressor. It keeps you informed of the amount of air delivered by the compressor. If your tank or tank is damaged, your readings will be wrong. If the pressure switch is damaged, it will not function properly and result in incorrect readings. Fortunately, there are some easy ways to fix this. To prevent this from happening, keep the tank pressure switch in good condition.
When the air pressure in the tank drops to the cut-in pressure setting, the switch allows power to flow through it. This will start the motor and pump of the air compressor. Then, if the pressure in the tank rises above the cut-off level, the switch will trip and stop the compressor. This will prevent it from being over-pressurized. Power flow will continue to flow to the motor. Depending on your compressor model, you can change the cut-in and cut-out pressures as needed.
energy source
The power supply of the air compressor is very important. Most air compressors run on 12 VDC, which is ideal for automotive use. Alternatively, you can buy a switching power supply for around $20. No matter which power supply you choose, you must ensure that it can support the maximum current of the compressor. You can find power supplies in all sizes, from quarter-horsepower to five-horsepower.
The voltage required for a three-phase air compressor will vary. Three-phase air compressors require three separate power cords and a three-phase electrical service panel. This is because a standard 120/240-volt electrical service panel is not sufficient to power a three-phase compressor. Additionally, three-phase compressors require three separate isolated wires for the engine and motor circuits. Three-phase compressors do not require a neutral wire.


editor by CX 2023-06-06
China High Pressure 16-40 Bar Fixed Speed Drive Oil Lubricated Electric Two Stage Rotary Double Screw Type Air Compressor Price air compressor price
Merchandise Description
Industrial Low-Noise Electric Stationary AC Electricity Oil Lubricated Medium Substantial Strain Immediate Driven Rotary Screw Variety Air Compressor Rewards
1.Excellent layout with 72 sorts of technologies patent, 2 phases compression, understand greatest vitality conserving and cheapest sounds level.
2.Point out-of-the-artwork screw component, unique Germany CZPT air finish, ladvanced SAP profile style, superior Sweden CZPT factor bearings
3.Adopts entire world-renowned parts, this kind of as Schneider electronics from France, DENAIR filters from Germany, CZPT stress sensor from Denmark, and many others. lead to guarantee the compressor longer services life.
4.Smart controller and multi-language LCD keep the excellent security
functionality.
five.Stainless metal oil pipe and air pipe, large temperature resistant (400ºC=752ºF) and lower temperature resistant(-270ºC=518ºF), large strain resistant.lUltra-long life(eighty a long time), completely leak free and servicing free of charge
six.Conform to CE, ISO9001 and vitality saving certification, and many others.
The Technological Parameters Of Substantial Pressure Rotary Screw Air Compressor
| Model | Maxinmum working strain | Capacity(Fad)* | Installed motor | Driving manner& Cooling approach |
Noise amount** | Dimensions(mm) | Weight | Air outlet pipe diameter |
|||||||||||
| 50 HZ | 60 HZ | power | |||||||||||||||||
| Min. | Max. | Min. | Max. | Min. | Max. | Min. | Max. | ||||||||||||
| bar(g) | psig | m³/min | cfm | m³/min | cfm | kw | hp | dB(A) | L | W | H | kg | |||||||
| DVAH-90-16 | 16 | 232 | three.seventy three | nine.24 | 131 | 326 | four.28 | eight.57 | 151 | 303 | 90 | 120 | Direct Driven Air Cooling /W-Drinking water Cooling |
78 | 2800 | 1600 | 1700 | 2500 | DN50 |
| DVAH-ninety-18 | eighteen | 261 | four.29 | 10.seventy three | 151 | 379 | five.39 | ten.seventy eight | a hundred ninety | 381 | ninety | one hundred twenty | seventy eight | 2800 | 1600 | 1700 | 2500 | DN50 | |
| DVAH-90-20 | 20 | 290 | four.24 | ten.61 | 150 | 375 | five.33 | ten.67 | 188 | 377 | ninety | 120 | 78 | 2800 | 1600 | 1700 | 2500 | DN50 | |
| DVAH-90-25 | twenty five | 363 | 4.14 | 10.35 | 146 | 365 | 4.seventy six | nine.51 | 168 | 336 | 90 | 120 | seventy eight | 2800 | 1600 | 1700 | 2500 | DN50 | |
| DVAH-110-16 | sixteen | 232 | 5.32 | thirteen.3 | 188 | 470 | five.eighty one | 11.sixty two | 205 | 410 | 110 | one hundred fifty | 78 | 2800 | 1600 | 1700 | 3200 | DN50 | |
| DVAH-one hundred ten-18 | eighteen | 261 | 5.78 | fourteen.45 | 204 | 510 | five.58 | 11.sixteen | 197 | 394 | a hundred and ten | 150 | 78 | 2800 | 1600 | 1700 | 3200 | DN50 | |
| DVAH-110-20 | 20 | 290 | five.seventy three | fourteen.33 | 202 | 506 | 5.38 | 10.seventy six | a hundred ninety | 380 | a hundred and ten | a hundred and fifty | seventy eight | 2800 | 1600 | 1700 | 3200 | DN50 | |
| DVAH-110-twenty five | 25 | 363 | 4.86 | twelve.fifteen | 172 | 429 | 5.28 | ten.fifty six | 186 | 373 | one hundred ten | one hundred fifty | 78 | 2800 | 1600 | 1700 | 3200 | DN50 | |
| DVAH-110-30 | thirty | 435 | four.95 | twelve.38 | a hundred seventy five | 437 | five.15 | ten.three | 182 | 364 | one hundred ten | a hundred and fifty | seventy eight | 2800 | 1600 | 1700 | 3200 | DN50 | |
| DVAH-110-35 | 35 | 508 | four.24 | 10.6 | one hundred fifty | 374 | five.one | ten.2 | 180 | 360 | one hundred ten | one hundred fifty | 78 | 2800 | 1600 | 1700 | 3200 | DN50 | |
| DVAH-110-40 | forty | 580 | 4.21 | ten.fifty three | 149 | 372 | five.six | 11.two | 198 | 395 | one hundred ten | one hundred fifty | seventy eight | 2800 | 1600 | 1700 | 3200 | DN50 | |
| DVAH-132-16 | sixteen | 232 | 5.35 | 13.37 | 189 | 472 | 7.25 | 14.five | 256 | 512 | 132 | one hundred seventy five | 78 | 2800 | 1600 | 1700 | 3950 | DN50 | |
| DVAH-132-eighteen | 18 | 261 | five.eighty one | 14.fifty three | 205 | 513 | 6.five | 12.ninety nine | 229 | 459 | 132 | a hundred seventy five | seventy eight | 2800 | 1600 | 1700 | 3950 | DN50 | |
| DVAH-132-twenty | 20 | 290 | 5.seventy five | 14.37 | 203 | 507 | six.42 | 12.84 | 227 | 453 | 132 | 175 | seventy eight | 2800 | 1600 | 1700 | 3950 | DN50 | |
| DVAH-132-25 | twenty five | 363 | four.87 | twelve.eighteen | 172 | 430 | 6.23 | twelve.forty six | 220 | 440 | 132 | a hundred seventy five | seventy eight | 2800 | 1600 | 1700 | 3950 | DN50 | |
| DVAH-132-thirty | 30 | 435 | 4.97 | twelve.forty three | 176 | 439 | five.twenty five | ten.five | 185 | 371 | 132 | 175 | seventy eight | 2800 | 1600 | 1700 | 3950 | DN50 | |
| DVAH-132-35 | 35 | 508 | 4.26 | 10.64 | 150 | 376 | 5.two | ten.4 | 184 | 367 | 132 | 175 | 78 | 2800 | 1600 | 1700 | 3950 | DN50 | |
| DVAH-132-40 | forty | 580 | 4.22 | ten.56 | 149 | 373 | 5.15 | 10.3 | 182 | 364 | 132 | a hundred seventy five | seventy eight | 2800 | 1600 | 1700 | 3950 | DN50 | |
| DVAH-one hundred sixty-16 | 16 | 232 | 6.seventeen | fifteen.43 | 218 | 545 | nine.39 | 18.seventy eight | 332 | 663 | a hundred and sixty | 215 | eighty | 2800 | 1600 | 2000 | 5000 | DN65 | |
| DVAH-a hundred and sixty-eighteen | eighteen | 261 | six.76 | 16.ninety one | 239 | 597 | 9.22 | eighteen.43 | 325 | 651 | 160 | 215 | 80 | 2800 | 1600 | 2000 | 5000 | DN65 | |
| DVAH-a hundred and sixty-20 | 20 | 290 | 6.66 | 16.65 | 235 | 588 | 8.07 | sixteen.13 | 285 | 570 | 160 | 215 | eighty | 2800 | 1600 | 2000 | 5000 | DN65 | |
| DVAH-160-25 | twenty five | 363 | five.89 | fourteen.seventy three | 208 | 520 | 7.ninety nine | fifteen.97 | 282 | 564 | 160 | 215 | 80 | 2800 | 1600 | 2000 | 5000 | DN65 | |
| DVAH-185-sixteen | 16 | 232 | six.fifty five | sixteen.37 | 231 | 578 | ten.3 | twenty.6 | 364 | 727 | 185 | 250 | 80 | 2800 | 1600 | 2000 | 5500 | DN65 | |
| DVAH-185-eighteen | eighteen | 261 | seven.29 | 18.21 | 321 | 643 | ten.19 | twenty.37 | 360 | 719 | 185 | 250 | eighty | 2800 | 1600 | 2000 | 5500 | DN65 | |
| DVAH-185-20 | 20 | 290 | seven.two | 18.01 | 254 | 636 | 8.eighty one | 17.sixty two | 311 | 622 | 185 | 250 | 80 | 2800 | 1600 | 2000 | 5500 | DN65 | |
| DVAH-185-twenty five | twenty five | 363 | 7.06 | 17.sixty five | 249 | 623 | eight.73 | 17.45 | 308 | 616 | 185 | 250 | eighty | 2800 | 1600 | 2000 | 5500 | DN65 | |
| DVAH-two hundred-sixteen | sixteen | 232 | 8.sixty eight | 21.seventy one | 307 | 766 | 11.94 | 23.88 | 422 | 843 | 200 | 270 | eighty five | 3300 | 2000 | 2100 | 6000 | DN80 | |
| DVAH-200-18 | 18 | 261 | ten.64 | 26.sixty one | 376 | 940 | 11.32 | 22.sixty four | four hundred | 799 | 200 | 270 | 85 | 3300 | 2000 | 2100 | 6000 | DN80 | |
| DVAH-200-20 | 20 | 290 | 9.seven | 24.25 | 343 | 856 | 10.69 | 21.37 | 377 | 755 | two hundred | 270 | 85 | 3300 | 2000 | 2100 | 6000 | DN80 | |
| DVAH-200-25 | twenty five | 363 | eight.84 | 22.09 | 312 | 780 | nine.one | 18.19 | 321 | 642 | two hundred | 270 | 85 | 3300 | 2000 | 2100 | 6000 | DN80 | |
| DVAH-220-sixteen | 16 | 232 | 9.75 | 24.37 | 344 | 860 | 12.seventeen | 24.34 | 430 | 859 | 220 | 300 | eighty five | 3300 | 2000 | 2100 | 6300 | DN80 | |
| DVAH-220-eighteen | eighteen | 261 | 12.thirteen | 30.32 | 428 | 1070 | eleven.eighty four | 23.67 | 418 | 836 | 220 | three hundred | eighty five | 3300 | 2000 | 2100 | 6300 | DN80 | |
| DVAH-220-twenty | 20 | 290 | 10.56 | 26.39 | 373 | 932 | 11.21 | 22.forty two | 396 | 792 | 220 | three hundred | eighty five | 3300 | 2000 | 2100 | 6300 | DN80 | |
| DVAH-220-25 | twenty five | 363 | 9.six | 24.01 | 339 | 848 | ten.forty seven | twenty.ninety four | 370 | 739 | 220 | 300 | eighty five | 3300 | 2000 | 2100 | 6300 | DN80 | |
| DVAH-250-16 | 16 | 232 | 10.seven | 26.75 | 378 | 944 | 14.07 | 28.13 | 497 | 993 | 250 | 350 | 85 | 3500 | 2200 | 2100 | 6500 | DN125 | |
| DVAH-250-eighteen | eighteen | 261 | twelve.13 | thirty.32 | 428 | 1070 | fourteen | 27.ninety nine | 494 | 988 | 250 | 350 | eighty five | 3500 | 2200 | 2100 | 6500 | DN125 | |
| DVAH-250-20 | twenty | 290 | 12.07 | thirty.sixteen | 426 | 1065 | twelve.95 | 25.89 | 457 | 914 | 250 | 350 | 85 | 3500 | 2200 | 2100 | 6500 | DN125 | |
| DVAH-250-25 | twenty five | 363 | ten.45 | 26.thirteen | 369 | 923 | twelve.forty five | 24.nine | 440 | 879 | 250 | 350 | 85 | 3500 | 2200 | 2100 | 6500 | DN125 | |
| DVAH-280-sixteen | 16 | 232 | twelve.55 | 31.38 | 443 | 1108 | sixteen.fifty one | 33.02 | 583 | 1166 | 280 | 375 | eighty five | 3500 | 2200 | 2100 | 7000 | DN125 | |
| DVAH-280-18 | eighteen | 261 | fourteen.99 | 37.forty seven | 529 | 1323 | fourteen.84 | 29.sixty eight | 524 | 1048 | 280 | 375 | 85 | 3500 | 2200 | 2100 | 7000 | DN125 | |
| DVAH-280-twenty | 20 | 290 | 14.eighty four | 37.09 | 524 | 1310 | 14.sixty nine | 29.38 | 519 | 1037 | 280 | 375 | eighty five | 3500 | 2200 | 2100 | 7000 | DN125 | |
| DVAH-280-25 | 25 | 363 | 12.37 | thirty.ninety three | 437 | 1092 | 12.69 | twenty five.38 | 448 | 896 | 280 | 375 | 85 | 3500 | 2200 | 2100 | 7000 | DN125 | |
| *) Fad in accordance with ISO 1217 : 2009, Annex C: Complete ingestion stress 1 bar (a), cooling and air consumption temperature 20 °C **) Sounds level as for each ISO 2151 and the fundamental regular ISO 9614-2, procedure at highest running stress and greatest speed tolerance: ± 3 dB(A) ***) Specs are matter to adjust without prior notice |
|||||||||||||||||||
DENAIR Factory
DENAIR Certificates
DENAIR Exhibiton
DENAIR Buyers
We Carefully Selected For You The Basic Circumstance:
DENAIR VSD Screw Air Compressor for Foodstuff Processing in United states of america
Task Identify: Coffee maker in Omaha, United States
Product Title: 30KW 40HP direct dirven variable frequency screw air compressor with air dryer and air receiver tank
Design No. & Qty: DVA-30G x 2
Doing work Time: From January, 2016 till now
Function: In January, 2016, CZPT support staff Michael, Sissi and Steven visited our VIP customer in Omaha, United States for technical instruction for air compressor routine maintenance. The consumer was really content with our great service and VSD power preserving solution.
FAQ
Q1: Are you manufacturing facility or trade company?
A1: We are manufacturing facility.
Q2: What the just deal with of your manufacturing facility?
A2: No. 366, YangzhuangBang Road, Pingxing Rd., Xindai City, HangZhou, ZHangZhoug Province, China
Q3: Warranty conditions of your device?
A3: Two many years warranty for the device and technological assist according to your wants.
Q4: Will you offer some spare components of the devices?
A4: Yes, of system.
Q5: How extended will you get to set up production?
A5: 380V 50HZ we can delivery the items inside ten days. Other electric power or other colour we will supply within 22 times
Q6: Can you acknowledge OEM orders?
A6: Yes, with professional style staff, OEM orders are very welcome.
|
/ Piece | |
1 Piece (Min. Order) |
###
|
Shipping Cost:
Estimated freight per unit. |
To be negotiated |
|---|
###
| Lubrication Style: | Lubricated |
|---|---|
| Cooling System: | Air Cooling |
| Power Source: | AC Power |
###
| Customization: |
|---|
###
| Model | Maxinmum working pressure | Capacity(FAD)* | Installed motor | Driving mode& Cooling method |
Noise level** | Dimensions(mm) | Weight | Air outlet pipe diameter |
|||||||||||
| 50 HZ | 60 HZ | power | |||||||||||||||||
| Min. | Max. | Min. | Max. | Min. | Max. | Min. | Max. | ||||||||||||
| bar(g) | psig | m³/min | cfm | m³/min | cfm | kw | hp | dB(A) | L | W | H | kg | |||||||
| DVAH-90-16 | 16 | 232 | 3.73 | 9.24 | 131 | 326 | 4.28 | 8.57 | 151 | 303 | 90 | 120 | Direct Driven Air Cooling /W-Water Cooling |
78 | 2800 | 1600 | 1700 | 2500 | DN50 |
| DVAH-90-18 | 18 | 261 | 4.29 | 10.73 | 151 | 379 | 5.39 | 10.78 | 190 | 381 | 90 | 120 | 78 | 2800 | 1600 | 1700 | 2500 | DN50 | |
| DVAH-90-20 | 20 | 290 | 4.24 | 10.61 | 150 | 375 | 5.33 | 10.67 | 188 | 377 | 90 | 120 | 78 | 2800 | 1600 | 1700 | 2500 | DN50 | |
| DVAH-90-25 | 25 | 363 | 4.14 | 10.35 | 146 | 365 | 4.76 | 9.51 | 168 | 336 | 90 | 120 | 78 | 2800 | 1600 | 1700 | 2500 | DN50 | |
| DVAH-110-16 | 16 | 232 | 5.32 | 13.3 | 188 | 470 | 5.81 | 11.62 | 205 | 410 | 110 | 150 | 78 | 2800 | 1600 | 1700 | 3200 | DN50 | |
| DVAH-110-18 | 18 | 261 | 5.78 | 14.45 | 204 | 510 | 5.58 | 11.16 | 197 | 394 | 110 | 150 | 78 | 2800 | 1600 | 1700 | 3200 | DN50 | |
| DVAH-110-20 | 20 | 290 | 5.73 | 14.33 | 202 | 506 | 5.38 | 10.76 | 190 | 380 | 110 | 150 | 78 | 2800 | 1600 | 1700 | 3200 | DN50 | |
| DVAH-110-25 | 25 | 363 | 4.86 | 12.15 | 172 | 429 | 5.28 | 10.56 | 186 | 373 | 110 | 150 | 78 | 2800 | 1600 | 1700 | 3200 | DN50 | |
| DVAH-110-30 | 30 | 435 | 4.95 | 12.38 | 175 | 437 | 5.15 | 10.3 | 182 | 364 | 110 | 150 | 78 | 2800 | 1600 | 1700 | 3200 | DN50 | |
| DVAH-110-35 | 35 | 508 | 4.24 | 10.6 | 150 | 374 | 5.1 | 10.2 | 180 | 360 | 110 | 150 | 78 | 2800 | 1600 | 1700 | 3200 | DN50 | |
| DVAH-110-40 | 40 | 580 | 4.21 | 10.53 | 149 | 372 | 5.6 | 11.2 | 198 | 395 | 110 | 150 | 78 | 2800 | 1600 | 1700 | 3200 | DN50 | |
| DVAH-132-16 | 16 | 232 | 5.35 | 13.37 | 189 | 472 | 7.25 | 14.5 | 256 | 512 | 132 | 175 | 78 | 2800 | 1600 | 1700 | 3950 | DN50 | |
| DVAH-132-18 | 18 | 261 | 5.81 | 14.53 | 205 | 513 | 6.5 | 12.99 | 229 | 459 | 132 | 175 | 78 | 2800 | 1600 | 1700 | 3950 | DN50 | |
| DVAH-132-20 | 20 | 290 | 5.75 | 14.37 | 203 | 507 | 6.42 | 12.84 | 227 | 453 | 132 | 175 | 78 | 2800 | 1600 | 1700 | 3950 | DN50 | |
| DVAH-132-25 | 25 | 363 | 4.87 | 12.18 | 172 | 430 | 6.23 | 12.46 | 220 | 440 | 132 | 175 | 78 | 2800 | 1600 | 1700 | 3950 | DN50 | |
| DVAH-132-30 | 30 | 435 | 4.97 | 12.43 | 176 | 439 | 5.25 | 10.5 | 185 | 371 | 132 | 175 | 78 | 2800 | 1600 | 1700 | 3950 | DN50 | |
| DVAH-132-35 | 35 | 508 | 4.26 | 10.64 | 150 | 376 | 5.2 | 10.4 | 184 | 367 | 132 | 175 | 78 | 2800 | 1600 | 1700 | 3950 | DN50 | |
| DVAH-132-40 | 40 | 580 | 4.22 | 10.56 | 149 | 373 | 5.15 | 10.3 | 182 | 364 | 132 | 175 | 78 | 2800 | 1600 | 1700 | 3950 | DN50 | |
| DVAH-160-16 | 16 | 232 | 6.17 | 15.43 | 218 | 545 | 9.39 | 18.78 | 332 | 663 | 160 | 215 | 80 | 2800 | 1600 | 2000 | 5000 | DN65 | |
| DVAH-160-18 | 18 | 261 | 6.76 | 16.91 | 239 | 597 | 9.22 | 18.43 | 325 | 651 | 160 | 215 | 80 | 2800 | 1600 | 2000 | 5000 | DN65 | |
| DVAH-160-20 | 20 | 290 | 6.66 | 16.65 | 235 | 588 | 8.07 | 16.13 | 285 | 570 | 160 | 215 | 80 | 2800 | 1600 | 2000 | 5000 | DN65 | |
| DVAH-160-25 | 25 | 363 | 5.89 | 14.73 | 208 | 520 | 7.99 | 15.97 | 282 | 564 | 160 | 215 | 80 | 2800 | 1600 | 2000 | 5000 | DN65 | |
| DVAH-185-16 | 16 | 232 | 6.55 | 16.37 | 231 | 578 | 10.3 | 20.6 | 364 | 727 | 185 | 250 | 80 | 2800 | 1600 | 2000 | 5500 | DN65 | |
| DVAH-185-18 | 18 | 261 | 7.29 | 18.21 | 321 | 643 | 10.19 | 20.37 | 360 | 719 | 185 | 250 | 80 | 2800 | 1600 | 2000 | 5500 | DN65 | |
| DVAH-185-20 | 20 | 290 | 7.2 | 18.01 | 254 | 636 | 8.81 | 17.62 | 311 | 622 | 185 | 250 | 80 | 2800 | 1600 | 2000 | 5500 | DN65 | |
| DVAH-185-25 | 25 | 363 | 7.06 | 17.65 | 249 | 623 | 8.73 | 17.45 | 308 | 616 | 185 | 250 | 80 | 2800 | 1600 | 2000 | 5500 | DN65 | |
| DVAH-200-16 | 16 | 232 | 8.68 | 21.71 | 307 | 766 | 11.94 | 23.88 | 422 | 843 | 200 | 270 | 85 | 3300 | 2000 | 2100 | 6000 | DN80 | |
| DVAH-200-18 | 18 | 261 | 10.64 | 26.61 | 376 | 940 | 11.32 | 22.64 | 400 | 799 | 200 | 270 | 85 | 3300 | 2000 | 2100 | 6000 | DN80 | |
| DVAH-200-20 | 20 | 290 | 9.7 | 24.25 | 343 | 856 | 10.69 | 21.37 | 377 | 755 | 200 | 270 | 85 | 3300 | 2000 | 2100 | 6000 | DN80 | |
| DVAH-200-25 | 25 | 363 | 8.84 | 22.09 | 312 | 780 | 9.1 | 18.19 | 321 | 642 | 200 | 270 | 85 | 3300 | 2000 | 2100 | 6000 | DN80 | |
| DVAH-220-16 | 16 | 232 | 9.75 | 24.37 | 344 | 860 | 12.17 | 24.34 | 430 | 859 | 220 | 300 | 85 | 3300 | 2000 | 2100 | 6300 | DN80 | |
| DVAH-220-18 | 18 | 261 | 12.13 | 30.32 | 428 | 1070 | 11.84 | 23.67 | 418 | 836 | 220 | 300 | 85 | 3300 | 2000 | 2100 | 6300 | DN80 | |
| DVAH-220-20 | 20 | 290 | 10.56 | 26.39 | 373 | 932 | 11.21 | 22.42 | 396 | 792 | 220 | 300 | 85 | 3300 | 2000 | 2100 | 6300 | DN80 | |
| DVAH-220-25 | 25 | 363 | 9.6 | 24.01 | 339 | 848 | 10.47 | 20.94 | 370 | 739 | 220 | 300 | 85 | 3300 | 2000 | 2100 | 6300 | DN80 | |
| DVAH-250-16 | 16 | 232 | 10.7 | 26.75 | 378 | 944 | 14.07 | 28.13 | 497 | 993 | 250 | 350 | 85 | 3500 | 2200 | 2100 | 6500 | DN125 | |
| DVAH-250-18 | 18 | 261 | 12.13 | 30.32 | 428 | 1070 | 14 | 27.99 | 494 | 988 | 250 | 350 | 85 | 3500 | 2200 | 2100 | 6500 | DN125 | |
| DVAH-250-20 | 20 | 290 | 12.07 | 30.16 | 426 | 1065 | 12.95 | 25.89 | 457 | 914 | 250 | 350 | 85 | 3500 | 2200 | 2100 | 6500 | DN125 | |
| DVAH-250-25 | 25 | 363 | 10.45 | 26.13 | 369 | 923 | 12.45 | 24.9 | 440 | 879 | 250 | 350 | 85 | 3500 | 2200 | 2100 | 6500 | DN125 | |
| DVAH-280-16 | 16 | 232 | 12.55 | 31.38 | 443 | 1108 | 16.51 | 33.02 | 583 | 1166 | 280 | 375 | 85 | 3500 | 2200 | 2100 | 7000 | DN125 | |
| DVAH-280-18 | 18 | 261 | 14.99 | 37.47 | 529 | 1323 | 14.84 | 29.68 | 524 | 1048 | 280 | 375 | 85 | 3500 | 2200 | 2100 | 7000 | DN125 | |
| DVAH-280-20 | 20 | 290 | 14.84 | 37.09 | 524 | 1310 | 14.69 | 29.38 | 519 | 1037 | 280 | 375 | 85 | 3500 | 2200 | 2100 | 7000 | DN125 | |
| DVAH-280-25 | 25 | 363 | 12.37 | 30.93 | 437 | 1092 | 12.69 | 25.38 | 448 | 896 | 280 | 375 | 85 | 3500 | 2200 | 2100 | 7000 | DN125 | |
| *) FAD in accordance with ISO 1217 : 2009, Annex C: Absolute intake pressure 1 bar (a), cooling and air intake temperature 20 °C **) Noise level as per ISO 2151 and the basic standard ISO 9614-2, operation at maximum operating pressure and maximum speed; tolerance: ± 3 dB(A) ***) Specifications are subject to change without prior notice |
|||||||||||||||||||
|
/ Piece | |
1 Piece (Min. Order) |
###
|
Shipping Cost:
Estimated freight per unit. |
To be negotiated |
|---|
###
| Lubrication Style: | Lubricated |
|---|---|
| Cooling System: | Air Cooling |
| Power Source: | AC Power |
###
| Customization: |
|---|
###
| Model | Maxinmum working pressure | Capacity(FAD)* | Installed motor | Driving mode& Cooling method |
Noise level** | Dimensions(mm) | Weight | Air outlet pipe diameter |
|||||||||||
| 50 HZ | 60 HZ | power | |||||||||||||||||
| Min. | Max. | Min. | Max. | Min. | Max. | Min. | Max. | ||||||||||||
| bar(g) | psig | m³/min | cfm | m³/min | cfm | kw | hp | dB(A) | L | W | H | kg | |||||||
| DVAH-90-16 | 16 | 232 | 3.73 | 9.24 | 131 | 326 | 4.28 | 8.57 | 151 | 303 | 90 | 120 | Direct Driven Air Cooling /W-Water Cooling |
78 | 2800 | 1600 | 1700 | 2500 | DN50 |
| DVAH-90-18 | 18 | 261 | 4.29 | 10.73 | 151 | 379 | 5.39 | 10.78 | 190 | 381 | 90 | 120 | 78 | 2800 | 1600 | 1700 | 2500 | DN50 | |
| DVAH-90-20 | 20 | 290 | 4.24 | 10.61 | 150 | 375 | 5.33 | 10.67 | 188 | 377 | 90 | 120 | 78 | 2800 | 1600 | 1700 | 2500 | DN50 | |
| DVAH-90-25 | 25 | 363 | 4.14 | 10.35 | 146 | 365 | 4.76 | 9.51 | 168 | 336 | 90 | 120 | 78 | 2800 | 1600 | 1700 | 2500 | DN50 | |
| DVAH-110-16 | 16 | 232 | 5.32 | 13.3 | 188 | 470 | 5.81 | 11.62 | 205 | 410 | 110 | 150 | 78 | 2800 | 1600 | 1700 | 3200 | DN50 | |
| DVAH-110-18 | 18 | 261 | 5.78 | 14.45 | 204 | 510 | 5.58 | 11.16 | 197 | 394 | 110 | 150 | 78 | 2800 | 1600 | 1700 | 3200 | DN50 | |
| DVAH-110-20 | 20 | 290 | 5.73 | 14.33 | 202 | 506 | 5.38 | 10.76 | 190 | 380 | 110 | 150 | 78 | 2800 | 1600 | 1700 | 3200 | DN50 | |
| DVAH-110-25 | 25 | 363 | 4.86 | 12.15 | 172 | 429 | 5.28 | 10.56 | 186 | 373 | 110 | 150 | 78 | 2800 | 1600 | 1700 | 3200 | DN50 | |
| DVAH-110-30 | 30 | 435 | 4.95 | 12.38 | 175 | 437 | 5.15 | 10.3 | 182 | 364 | 110 | 150 | 78 | 2800 | 1600 | 1700 | 3200 | DN50 | |
| DVAH-110-35 | 35 | 508 | 4.24 | 10.6 | 150 | 374 | 5.1 | 10.2 | 180 | 360 | 110 | 150 | 78 | 2800 | 1600 | 1700 | 3200 | DN50 | |
| DVAH-110-40 | 40 | 580 | 4.21 | 10.53 | 149 | 372 | 5.6 | 11.2 | 198 | 395 | 110 | 150 | 78 | 2800 | 1600 | 1700 | 3200 | DN50 | |
| DVAH-132-16 | 16 | 232 | 5.35 | 13.37 | 189 | 472 | 7.25 | 14.5 | 256 | 512 | 132 | 175 | 78 | 2800 | 1600 | 1700 | 3950 | DN50 | |
| DVAH-132-18 | 18 | 261 | 5.81 | 14.53 | 205 | 513 | 6.5 | 12.99 | 229 | 459 | 132 | 175 | 78 | 2800 | 1600 | 1700 | 3950 | DN50 | |
| DVAH-132-20 | 20 | 290 | 5.75 | 14.37 | 203 | 507 | 6.42 | 12.84 | 227 | 453 | 132 | 175 | 78 | 2800 | 1600 | 1700 | 3950 | DN50 | |
| DVAH-132-25 | 25 | 363 | 4.87 | 12.18 | 172 | 430 | 6.23 | 12.46 | 220 | 440 | 132 | 175 | 78 | 2800 | 1600 | 1700 | 3950 | DN50 | |
| DVAH-132-30 | 30 | 435 | 4.97 | 12.43 | 176 | 439 | 5.25 | 10.5 | 185 | 371 | 132 | 175 | 78 | 2800 | 1600 | 1700 | 3950 | DN50 | |
| DVAH-132-35 | 35 | 508 | 4.26 | 10.64 | 150 | 376 | 5.2 | 10.4 | 184 | 367 | 132 | 175 | 78 | 2800 | 1600 | 1700 | 3950 | DN50 | |
| DVAH-132-40 | 40 | 580 | 4.22 | 10.56 | 149 | 373 | 5.15 | 10.3 | 182 | 364 | 132 | 175 | 78 | 2800 | 1600 | 1700 | 3950 | DN50 | |
| DVAH-160-16 | 16 | 232 | 6.17 | 15.43 | 218 | 545 | 9.39 | 18.78 | 332 | 663 | 160 | 215 | 80 | 2800 | 1600 | 2000 | 5000 | DN65 | |
| DVAH-160-18 | 18 | 261 | 6.76 | 16.91 | 239 | 597 | 9.22 | 18.43 | 325 | 651 | 160 | 215 | 80 | 2800 | 1600 | 2000 | 5000 | DN65 | |
| DVAH-160-20 | 20 | 290 | 6.66 | 16.65 | 235 | 588 | 8.07 | 16.13 | 285 | 570 | 160 | 215 | 80 | 2800 | 1600 | 2000 | 5000 | DN65 | |
| DVAH-160-25 | 25 | 363 | 5.89 | 14.73 | 208 | 520 | 7.99 | 15.97 | 282 | 564 | 160 | 215 | 80 | 2800 | 1600 | 2000 | 5000 | DN65 | |
| DVAH-185-16 | 16 | 232 | 6.55 | 16.37 | 231 | 578 | 10.3 | 20.6 | 364 | 727 | 185 | 250 | 80 | 2800 | 1600 | 2000 | 5500 | DN65 | |
| DVAH-185-18 | 18 | 261 | 7.29 | 18.21 | 321 | 643 | 10.19 | 20.37 | 360 | 719 | 185 | 250 | 80 | 2800 | 1600 | 2000 | 5500 | DN65 | |
| DVAH-185-20 | 20 | 290 | 7.2 | 18.01 | 254 | 636 | 8.81 | 17.62 | 311 | 622 | 185 | 250 | 80 | 2800 | 1600 | 2000 | 5500 | DN65 | |
| DVAH-185-25 | 25 | 363 | 7.06 | 17.65 | 249 | 623 | 8.73 | 17.45 | 308 | 616 | 185 | 250 | 80 | 2800 | 1600 | 2000 | 5500 | DN65 | |
| DVAH-200-16 | 16 | 232 | 8.68 | 21.71 | 307 | 766 | 11.94 | 23.88 | 422 | 843 | 200 | 270 | 85 | 3300 | 2000 | 2100 | 6000 | DN80 | |
| DVAH-200-18 | 18 | 261 | 10.64 | 26.61 | 376 | 940 | 11.32 | 22.64 | 400 | 799 | 200 | 270 | 85 | 3300 | 2000 | 2100 | 6000 | DN80 | |
| DVAH-200-20 | 20 | 290 | 9.7 | 24.25 | 343 | 856 | 10.69 | 21.37 | 377 | 755 | 200 | 270 | 85 | 3300 | 2000 | 2100 | 6000 | DN80 | |
| DVAH-200-25 | 25 | 363 | 8.84 | 22.09 | 312 | 780 | 9.1 | 18.19 | 321 | 642 | 200 | 270 | 85 | 3300 | 2000 | 2100 | 6000 | DN80 | |
| DVAH-220-16 | 16 | 232 | 9.75 | 24.37 | 344 | 860 | 12.17 | 24.34 | 430 | 859 | 220 | 300 | 85 | 3300 | 2000 | 2100 | 6300 | DN80 | |
| DVAH-220-18 | 18 | 261 | 12.13 | 30.32 | 428 | 1070 | 11.84 | 23.67 | 418 | 836 | 220 | 300 | 85 | 3300 | 2000 | 2100 | 6300 | DN80 | |
| DVAH-220-20 | 20 | 290 | 10.56 | 26.39 | 373 | 932 | 11.21 | 22.42 | 396 | 792 | 220 | 300 | 85 | 3300 | 2000 | 2100 | 6300 | DN80 | |
| DVAH-220-25 | 25 | 363 | 9.6 | 24.01 | 339 | 848 | 10.47 | 20.94 | 370 | 739 | 220 | 300 | 85 | 3300 | 2000 | 2100 | 6300 | DN80 | |
| DVAH-250-16 | 16 | 232 | 10.7 | 26.75 | 378 | 944 | 14.07 | 28.13 | 497 | 993 | 250 | 350 | 85 | 3500 | 2200 | 2100 | 6500 | DN125 | |
| DVAH-250-18 | 18 | 261 | 12.13 | 30.32 | 428 | 1070 | 14 | 27.99 | 494 | 988 | 250 | 350 | 85 | 3500 | 2200 | 2100 | 6500 | DN125 | |
| DVAH-250-20 | 20 | 290 | 12.07 | 30.16 | 426 | 1065 | 12.95 | 25.89 | 457 | 914 | 250 | 350 | 85 | 3500 | 2200 | 2100 | 6500 | DN125 | |
| DVAH-250-25 | 25 | 363 | 10.45 | 26.13 | 369 | 923 | 12.45 | 24.9 | 440 | 879 | 250 | 350 | 85 | 3500 | 2200 | 2100 | 6500 | DN125 | |
| DVAH-280-16 | 16 | 232 | 12.55 | 31.38 | 443 | 1108 | 16.51 | 33.02 | 583 | 1166 | 280 | 375 | 85 | 3500 | 2200 | 2100 | 7000 | DN125 | |
| DVAH-280-18 | 18 | 261 | 14.99 | 37.47 | 529 | 1323 | 14.84 | 29.68 | 524 | 1048 | 280 | 375 | 85 | 3500 | 2200 | 2100 | 7000 | DN125 | |
| DVAH-280-20 | 20 | 290 | 14.84 | 37.09 | 524 | 1310 | 14.69 | 29.38 | 519 | 1037 | 280 | 375 | 85 | 3500 | 2200 | 2100 | 7000 | DN125 | |
| DVAH-280-25 | 25 | 363 | 12.37 | 30.93 | 437 | 1092 | 12.69 | 25.38 | 448 | 896 | 280 | 375 | 85 | 3500 | 2200 | 2100 | 7000 | DN125 | |
| *) FAD in accordance with ISO 1217 : 2009, Annex C: Absolute intake pressure 1 bar (a), cooling and air intake temperature 20 °C **) Noise level as per ISO 2151 and the basic standard ISO 9614-2, operation at maximum operating pressure and maximum speed; tolerance: ± 3 dB(A) ***) Specifications are subject to change without prior notice |
|||||||||||||||||||
How to Repair and Maintain an Air Compressor
A compressor is a device used to move air from one place to another. Air enters the air compressor through the intake valve. Inside the compressor, the vanes on the inner rotor rotate within an eccentric cavity. The self-adjusting length arm divides the space into multiple cavities of different sizes. As the rotor rotates, air fills the cavity. As air flows around the cavity, it builds pressure and is squeezed out of the compressor output.
Positive displacement
Positive displacement air compressors use reciprocating pistons to compress air. Gas is drawn in during the suction stroke and compressed by moving the piston in the opposite direction. It then discharges the compressed air by moving it in the opposite direction. This type of air compressor is most commonly found in automobiles, refrigerators, and other applications that require high pressure. However, it is not as efficient as a centrifugal compressor.
Most modern air compressors use positive displacement. Positive displacement models capture a volume of air in the compression chamber and distribute it when the pump is operating at maximum capacity. They are more economical than their negative displacement counterparts. Reciprocating screw air compressors are the most common positive displacement compressors. The reciprocating screw air compressor adopts a water jacket around the cylinder and is often used in processes such as oil drilling.
A bicycle pump is an example of positive displacement compression. Air is drawn into the cylinder and compressed by the moving piston. A piston compressor works on the same principle, but it uses a rotating crankshaft or connecting rod to complete the movement of the pistons. There are two types of positive displacement compressors: single-acting and double-acting. Both types work on the same principle, both are positive displacement compressors. The difference between the two types is the pressure ratio.
In air compression, positive displacement compression reduces the volume of the fluid and reduces its viscosity. This results in higher pressure ratios and is used in centrifugal, axial, and scroll compressors. Positive displacement is a common feature of most air compressors. Positive displacement compressors offer the same benefits and are more energy-efficient when applied to oil-free and gas applications. This type of compression is usually the best choice for low-pressure applications.
oil free
If you’re looking for an air compressor for your business, consider an oil-free air compressor. These models offer cleaner, quieter operation than traditional air compressors and require less maintenance. They also meet ISO Class 0 or Class 1 air purity requirements. Oil-free air compressors are also quieter, with fewer moving parts and less noise. These advantages make oil-free air compressors an ideal solution for many commercial applications.
Air purity is critical in many industries. Even the tiniest drop of oil can damage production equipment or damage products. The best way to find an oil-free air compressor for your business is to consider the process and end product. As air quality improves, more and more businesses are turning to oil-free compressors. Some of the advantages and disadvantages of these air compressors are:
When choosing an oil-free air compressor, it is important to understand the terminology used in the industry. Knowing these terms will make it easier for you to choose the right compressor for your needs. ACTFM, or actual cubic feet per minute, is an industry term for measuring the amount of air pumped in one minute under rated conditions. Although a simple number, it can be very useful in determining which type of air compressor is best for your application.
The ISO 8573-1 international standard defines air quality and provides air purity classifications. The strictest classification is air purity class 0. Many manufacturers claim that oil-free air compressors meet this standard. However, a class 0 oil-free air compressor does not necessarily mean that the air is free of contaminants. In fact, Class 0 is the benchmark for air purity. While zero air quality is the highest level, that doesn’t mean it’s completely oil-free.
double acting
A double-acting air compressor is a device that uses compressed air to generate electricity. Its working principle is based on piston and connecting rod. The connecting rod connects the crankshaft to the piston through pins and caps. The piston moves as the piston moves. Rods are usually made of forged carbon steel. In terms of service and maintenance, double-acting compressors require regular vise maintenance and proper cleaning.
The displacement of the compressor is a measure of the displacement that the piston can produce in a certain period of time. Displacement is usually expressed in actual cubic feet per minute. The exact calculation depends on the type of cylinder and the configuration of the compressor. Single-acting cylinders can have head-end or crank-end displacement, both of which can be measured using the displacement equation. A double-acting air compressor will use this equation. 4 and 6 calculate the displacement.
Double-acting air compressors have multiple cylinders and are made of cast iron. They are water-cooled and have a mechanical connection between the piston and connecting rod. A double-acting compressor compresses air twice per revolution of the motor. One cylinder moves up, while the other cylinder moves down. The piston moves down, allowing air to enter through valve #1. During the operation of the compressor, the temperature of the air and gas increases.
Double-acting air compressors typically have high pressure and are considered workhorses. Double-acting compressors also feature intercooling and double compression. As a result, these machines tend to last longer than single-acting compressors. Its low speed and dual compression make it a workhorse in the compressor industry. Double-acting air compressors are workhorses and versatile devices.
fuel tank pressure switch
You can adjust the pressure in the air compressor tank by adjusting the differential pressure. You can turn the mainspring clockwise or counterclockwise to increase or decrease the pressure. This valve will open when the pressure is low enough to start the compressor. If the pressure is too low, the valve should be closed. The cut-in and cut-out pressures should be set to appropriate values. After adjusting the tank pressure, check the hysteresis of the tank pressure switch and set the desired shutoff pressure.
If the pressure in the tank falls below the cut-in level, the tank pressure switch must be replaced. You can test the switch with a multimeter. Make sure the switch is not damaged. If you can’t find the switch, you can look at the other sections. If you find any damaged or missing parts, you should replace them. Otherwise, it may be time to check the tank pressure switch. You may need to disassemble the compressor and remove the switch.
The fuel tank pressure switch is an important part of the air compressor. It keeps you informed of the amount of air delivered by the compressor. If your tank or tank is damaged, your readings will be wrong. If the pressure switch is damaged, it will not function properly and result in incorrect readings. Fortunately, there are some easy ways to fix this. To prevent this from happening, keep the tank pressure switch in good condition.
When the air pressure in the tank drops to the cut-in pressure setting, the switch allows power to flow through it. This will start the motor and pump of the air compressor. Then, if the pressure in the tank rises above the cut-off level, the switch will trip and stop the compressor. This will prevent it from being over-pressurized. Power flow will continue to flow to the motor. Depending on your compressor model, you can change the cut-in and cut-out pressures as needed.
energy source
The power supply of the air compressor is very important. Most air compressors run on 12 VDC, which is ideal for automotive use. Alternatively, you can buy a switching power supply for around $20. No matter which power supply you choose, you must ensure that it can support the maximum current of the compressor. You can find power supplies in all sizes, from quarter-horsepower to five-horsepower.
The voltage required for a three-phase air compressor will vary. Three-phase air compressors require three separate power cords and a three-phase electrical service panel. This is because a standard 120/240-volt electrical service panel is not sufficient to power a three-phase compressor. Additionally, three-phase compressors require three separate isolated wires for the engine and motor circuits. Three-phase compressors do not require a neutral wire.


editor by CX 2023-03-28
China Hot selling 200 Kw 270 HP High Efficiency 7 Bar 8 Bar 10 Bar Electric Stationary Water Cooling Direct Drive Oil Less Rotary Single Screw Type Pm VSD Air Compressor near me shop
Solution Description
2~40bar Direct-DRIVE Water-INJECTED OIL-FREE SCREW AIR COMPRESSOR (PM VSD)
one. Lower temperature signifies much more effectiveness
With an exceptionally minimal working temperature of less than 60ºC, near isothermal compression is attained.
The excellent cooling ability of water gets rid of the warmth and gives more air per kW of power.
This also eliminates the need to have for an internal cooler and aftercooler, the CZPT power intake decreases pressure fall to a minimum.
two. Chopping the maintenance expense
Spare areas only want air filter factors and drinking water filter elements
Minimal running temperature makes certain the lengthy provider life of the screw air stop, keeping away from costly routine maintenance fees for the screw rotor.
Reduced temperature lowers the stress on other parts making sure lengthy daily life.
3. Steering clear of the charges of additional CZPT to fight strain drop
These fees, although not evident at the time of acquire, are really large and lead considerably to the complete expense of possession.
four. No Gearbox No require for CZPT oil lubrication.
5. Simple structure
Much less shifting elements than the dry oil-free of charge screw air compressor, indicating there is less to go incorrect,
while balance bearing hundreds lengthen the compression element services lifestyle for reduced-expense operation.
Product Parameters
Item Description
Company Profile
Scorching Sale Goods
2~10bar Oil-injected 7~16bar All-in-1 Small One-stage
Screw Air Compressor Screw Air Compressor Screw Air Compressor
2~40bar 100% Oil-free 8~12bar 100% Oil-free Diesel Engine Moveable
Screw Air Compressor Scroll Air Compressor Screw Air Compressor
Main Item
What we can supply:
* Oil-injected Screw Air Compressor (2~16 bar)
* All-in-1 Screw Air Compressor with Tank, Dryer, and Filters (7~16 bar)
* Single-phase Modest Screw Air Compressor for Residence use (8~10 bar)
* H2o-injected Oil-totally free Screw Air Compressor (2~forty bar)
* Oil-free Scroll Air Compressor (8~twelve bar)
* Diesel&Electrical Engine Transportable Screw Air Compressor (8~thirty bar)
* Air Dryer, Air tank, Filters, and other Spare parts
What to Look For When Purchasing an Air Compressor
An air compressor is a quite helpful resource that can assist you comprehensive several diverse kinds of construction jobs. This helpful equipment makes many jobs much easier, but not all of them are produced similarly. Knowing what to appear for when purchasing an air compressor will aid you make an educated selection. Right here are some of the factors you ought to search for. These incorporate price tag, measurement, and energy performance. Also, make positive to contemplate the air compressor’s sort.
One-stage air compressors are quieter
When it comes to sounds amount, one-stage air compressors are the way to go. These equipment have much less moving areas and are quieter than two-stage versions. One-phase air compressors use an axial circulation design and can be quieter than their twin-stage counterparts. Solitary-stage air compressors can run for a longer time and at lower pressures. One-stage air compressors can be utilized for light-weight industrial purposes. They have a prolonged daily life expectancy, with some versions lasting for in excess of a few thousand hours.
Even though some one-stage air compressors are quieter than two-stage air compressors, equally types have sounds-reduction functions. One particular type functions rubber components, which are created to dampen sounds. An additional attribute helps make a compressor quieter: its location around the job site. Some versions feature rubber base plugs and rubber mats to decrease floor vibrations. In addition to using these characteristics, solitary-phase compressors are less complicated to transport.
Sounds amounts are essential when selecting an air compressor. Some machines are as well noisy for comfy perform, and some businesses will not want to expose consumers to sound-producing air compressors. Other noise ranges can even endanger workers’ wellness. Single-stage air compressors are more cost-effective than dual-phase compressors. They are also quieter and a lot more powerful. But be ready for the sounds. Some single-phase air compressors are still noisy.
When compared to their two-phase counterparts, one-stage compressors are quieter when running at full capacity. Nevertheless, double-stage compressors are quieter on minimal capacities than solitary-stage units. These with variable velocity are quietest at reduced capacities. The variation is about 10db. If you’re anxious about the noise degree, you should think about a two-stage air compressor. But if you have a small workshop, it could not be ideal for you.
One-phase air compressors are normally far more effective than two-stage air compressors. The sound from a two-stage air compressor is lower due to the fact there’s no intermediate stage. Solitary-stage air compressors also use a piston that rotates in a single stage, even though twin-stage air compressors, also recognized as duplex models, are more successful. A one-phase air compressor is quieter, but double-phase compressors are louder.
Two-phase air compressors are far more energy efficient
Two-phase air compressors are much more vitality-efficient than solitary-stage devices. The efficiency of two-stage air compressors is elevated by way of a mixture of enhanced efficiency and increased longevity. These machines can keep much more air and have increased compression ratios. One particular product of a two-phase compressor can keep about 83 cubic toes of air at 100 PSI and 120 cubic toes at 150 PSI. A two-phase compressor is also quieter.
Two-phase air compressors are much more energy-productive because they have two pistons as an alternative of one. These air compressors accomplish a larger pressure rating and recover far more speedily. This variety of compressor is ideal for jobs that require higher air pressure for a prolonged period of time. In addition, they can operate several resources simultaneously. This helps make them far better for commercial and industrial use. Outlined below are some benefits of two-stage air compressors.
Single-stage air compressors can energy instruments in the garage or kitchen, but they are not as reliable for industrial purposes. One-stage compressors have more substantial elements that tend to encounter condensation. Additionally, single-phase compressors do not final long in steady use and are less power-efficient than two-phase types. Whether you happen to be using the compressor for a single tradesperson, a little crew, or a huge building crew, two-stage compressors are the very best selection.
One-phase air compressors are typically employed in little-scale foodstuff preparing and manufacturing. Single-stage air compressors are straightforward to transport between areas, and can be plugged into numerous electrical stores. One-stage compressors are also best for substantial-volume foodstuff processing. A dual-stage air compressor is perfect for industrial use. In some situations, you can even transfer the one-stage air compressor between two-phase air compressors.
Single-stage compressors typically cycle too swiftly, drawing a lot more electrical energy than two-phase models. A variable speed device stays on a reduced pace for several hours at a time. Solitary-stage air conditioners drive you to reduced your thermostat configurations although one-phase air conditioners run also usually. Equally models are power-successful but they are not as strength-successful as variable-velocity compressors. The major distinction is that one-stage air conditioners are inclined to drain the electricity source quicker.
Piston-pushed air compressors are quieter
A piston-driven air compressor is one particular of the quietest varieties of air compressors. It is much less noisy than reciprocating air compressors. A piston-pushed air compressor can attain sixty two decibels, although a scroll compressor is close to 50 % that quantity. The two primary components of a scroll air compressor are the piston and the helical screw. These air compressors are the two quite productive and peaceful.
More mature compressors are exceptionally noisy. They generate a “wumpa” sounds similar to a large engine. They are also capable of producing a high-pitched whine. These noises can be deafening, especially in a tiny workshop. That’s why it truly is vital to look for a silent compressor. But what can make a compressor peaceful? Go through on to find out more about this essential device.
Another big difference between piston-driven air compressors and electrical-driven air compressors is the electrical power supply. Electric air compressors create much less sound than gas-driven compressors, which use an engine. Piston-driven air compressors are also much more effective. They also create much less warmth, generating them an excellent decision for places of work and other options the place noise is a problem. The best way to decide amongst the two kinds of air compressors is to verify the manufacturer’s warranty and go through the ‘Description’.
Sounds reduction is the initial priority of a compressor’s operator, so make positive that you have the correct product. If you’re working on something delicate, never area the compressor way too close to a developing the place people might be close by. Noise can be quite disruptive to the workspace and can trigger health problems. To help fight sounds, you will require to acquire a peaceful air compressor. And will not overlook to contemplate its place: Piston-pushed air compressors are quieter than their reciprocating counterparts.
Piston-pushed air compressors are tranquil since the piston is produced of thin steel and more rubber, which absorbs the sound. In contrast to reciprocating air compressors, piston-pushed air compressors are much more efficient than their dual-piston cousins, which are quieter and a lot more powerful. So which kind is correct for you? Take a search at some of the major distinctions between the two. If you want a quiet compressor, make certain it satisfies the requirements necessary by the work you’re doing work on.
Oil-lubricated air compressors are a lot more price-successful
There are a number of factors why oil-lubricated air compressors are more costly than dry-variety air compressors. Initial of all, oil-lubricated air compressors have a tendency to be more reliable and peaceful. Additionally, oil-lubricated air compressors require much less components and can very last for a longer time than dry-kind air compressors. These are just a number of of the numerous rewards of making use of oil-lubricated air compressors.
Oil-free of charge air compressors have some down sides. They are less durable and may possibly not be as effective as oil-lubricated types. In addition, since oil-lubricated air compressors use oil, they can get quite noisy. While they are significantly less high-priced, they are not the best selection for heavy-duty operate. Even so, modern day oil-free air compressors have soundproofing and are suited for industrial use.
When purchasing an oil-lubricated air compressor, make certain to decide on one with a tank capability that fulfills your requirements and your room. Greater tanks can be much more costly than little tanks, but greater models are easier to shift close to. Also, be confident to take into account the weight and size of the portable air compressors when producing your selection. If the bodyweight is way too massive, you could have problems carrying it from place to location.
Yet another gain of making use of oil-lubricated air compressors is their decreased require for oil. These designs can previous up to a ten years longer than oil-free of charge counterparts. Oil-free air compressors are a lot more reasonably priced and can achieve the very same high overall performance as their oil-lubricated counterparts. Numerous industrial applications benefit from these air compressors. So, which 1 is correct for you? We’ve listed a few of them below.
An additional gain of selecting an oil-lubricated air compressor is the decreased value of maintenance. This type is a lot more tough than its oil-lubricated counterparts, which demand standard oil changes to maintain them working effortlessly. Nevertheless, it is not possible to transport an oil-lubricated compressor, which indicates that you need to set up it permanently to keep it doing work efficiently. In addition, these air compressors are difficult to go and are not transportable, which can limit your capacity to use it in a pinch.


China Hot selling Electric Powered Movable Rotary Screw Type Air Compressor for Coal Mining Industry near me factory
Item Description
Electrical Engine Portable Rotary Screw Air Compressor
Merchandise Parameters
Product Description
Very hot Sale Items
2~10bar Oil-injected 7~16bar All-in-1 Small Solitary-period
Screw Air Compressor Screw Air Compressor Screw Air Compressor
two~40bar 100% Oil-free 8~12bar a hundred% Oil-free Diesel Engine Transportable
Screw Air Compressor Scroll Air Compressor Screw Air Compressor
Main Product
What we can offer:
* Oil-injected Screw Air Compressor (2~16 bar)
* All-in-1 Screw Air Compressor with Tank, Dryer, and Filters (7~16 bar)
* One-period Modest Screw Air Compressor for House use (8~ten bar)
* Drinking water-injected Oil-totally free Screw Air Compressor (2~forty bar)
* Oil-free Scroll Air Compressor (8~12 bar)
* Diesel&Electric Motor Moveable Screw Air Compressor (8~30 bar)
* Air Dryer, Air tank, Filters, and other Spare components
How to Choose the Appropriate Air Compressor
An air compressor employs pressurized air to electrical power a selection of equipment. They are most typically used to power nailers and effect wrenches. Other well-liked employs for air compressors include paint sprayers and influence wrenches. Whilst all air compressors have the same simple design, their specialty differs. Ultimately, their distinctions arrive down to the sum of air they can drive. Read on for information on each sort of air compressor. These instruments are wonderful for many distinct functions, and picking the right air compressor is dependent on your particular needs.
Electric powered motor
While buying an electric powered motor for air compressor, compatibility is a important factor. Not all motors operate with the same kind of air compressor, so it truly is essential to examine the manufacturer’s instructions ahead of acquiring. By undertaking this, you can steer clear of throwing away money on an incompatible motor. An additional crucial consideration is velocity. A motor’s speed is its charge of rotation, calculated in revolutions for each minute. It is critical that you obtain a motor with adequate pace to meet up with the requirements of your air compressor.
Generally, an electric motor for air compressor is 1.5 hp. It is excellent for use with health care gear and metallic-reducing devices. It also performs well underneath constant procedure and gives a high effectiveness and strength-conserving efficiency. Additionally, it features an appealing price tag, generating it a very good option for a wide selection of apps. If you are hunting for a motor for an air compressor, search no further than a ZYS sequence.
A motor’s security class implies how the motor will operate. Safety lessons are specified by the IEC 60034-5. These are stated with two digits and symbolize the safety in opposition to strong objects and water. For example, an IP23 ranking signifies that the motor will be safeguarded from reliable objects, although IP54 indicates that it will shield from dust and h2o sprayed from all directions. It is vital to choose a motor with the correct protection course for your air compressor.
When choosing an electrical motor, you must consider no matter whether it’s appropriate with the model of air compressor. Some may possibly be suitable, while others could demand sophisticated electronics abilities to mend. Even so, most air compressors are protected by warranty, so it really is essential to examine with the company if the warranty is nevertheless in impact just before you invest a dime on a substitution. The motor must be changed if it has unsuccessful to perform as designed.
Oil tub
Air compressors call for suitable lubrication to function successfully. The piston must attract air with small friction. Dependent on their layout, air compressors can both be oil-lubricated or oil-free. The former makes use of oil to reduce piston friction, even though the latter splashes it on the cylinder bearings and partitions. This kind of air compressors are commonly acknowledged as oil-flooded air compressors. In get to preserve their oil baths thoroughly clean, they are advisable for use in areas with large dust ranges.
Begin/quit management
An air compressor can be managed by a begin/cease handle. This sort of management sends a signal to the principal motor that activates the compressor when the desire for air falls beneath a preset limit. This handle technique is effective for more compact air compressors and can be beneficial for decreasing strength charges. Commence/end manage is most effective in programs exactly where air stress does not adjust usually and exactly where the compressor is not needed to operate continuously.
To troubleshoot this dilemma, you want to check the electrical power provide of your compressor. To check the supply facet, use a voltage check to establish if electricity is flowing to the compressor. Make certain that the electricity supply to the compressor is regular and secure at all times. If it fluctuates, the compressor may possibly not commence or stop as predicted. If you can not discover the issue with the air compressor energy provide, it might be time to substitute it.
In addition to the start off/quit manage, you may possibly want to obtain extra air receivers for your air compressor. These can enhance the ability of air stored and minimize the variety of instances it starts off and stops. Another way to lessen the variety of commences for each hour is to include much more air receivers. Then, you can change the management to match your requirements. You can also install a stress gauge that monitors the compressor’s overall performance.
Begin/stop management for air compressors can be sophisticated, but the standard elements are relatively effortless to realize. One particular way to check them is to turn the compressor on or off. It is generally situated on the exterior of the motor. If you’re doubtful of the place of these factors, check out the capacitors and make certain that the air compressor is not managing while you might be not utilizing it. If it does, try out to eliminate the capacitor.
Variable displacement handle is another way to adjust the volume of air flowing into the compressor. By controlling the volume of air, the manage can delay the use of further compressors until finally a lot more needed air is accessible. In addition to this, the gadget can also keep an eye on the strength utilized in the compressor. This handle technique can result in significant vitality financial savings. You can even preserve on the quantity of electricity by employing variable displacement management. It is vital for effective compressed air techniques.
Variable pace generate
A VFD, or variable frequency drive, is a kind of electrical motor that adjusts its pace to match the demand for air. It is an effective way to minimize vitality costs and boost method trustworthiness. In fact, research have proven that a twenty% reduction in motor pace can conserve up to fifty% of vitality. In addition, a VFD can keep track of additional variables such as compressor oil strain and motor temperature. By reducing guide checks, a VFD will boost the efficiency of the software and minimize functioning expenses.
In addition to minimizing power expenses, variable-speed drives also enhance productiveness. A variable-velocity air compressor minimizes the risk of program leaks by 30 p.c. It also lowers the threat of technique leaks by decreasing stress in the system. Because of these advantages, several governments are selling this technology in their industries. Numerous even offer you incentives to support firms improve to variable-pace drives. For that reason, the variable-velocity push can gain a lot of air compressor installations.
One particular significant gain of a variable-velocity travel is its capability to optimize vitality use. Variable frequency drives are ready to ramp up and down to match the demand from customers for air. The purpose is to enhance the force and flow in the program so that the greatest “lifeless band” takes place between forty % and eighty per cent of entire load. A variable-speed compressor will also improve vitality efficiency due to the fact of its programmability.
A variable-speed air compressor can also be utilized to control the sum of air that is compressed by the system. This attribute adjusts the frequency of energy provided to the motor dependent on the desire. If the desire for air is low, the frequency of the motor will lessen to help save strength. On the other hand, if there is an extra demand from customers for air, the variable-velocity compressor will increase its pace. In addition, this variety of air compressor is much more productive than its fastened-velocity counterpart.
A VFD has numerous rewards for compressed air programs. Very first, it helps stabilize the force in the pipe community, thereby reducing the electricity losses owing to upstream strain. It also helps lessen the electrical power use brought on by fluctuations in upward stress. Its rewards are also far-achieving. And as long as the air stress and air provide is properly sized, a VFD will support enhance the performance of compressed air techniques.

